Function of miniature circuit breaker - Short circuit and leakage protection - [Wickway]

Small circuit breakers are used in various electrical applications, and they are installed in every household, whether in the industrial or communication industriesFunction of miniature circuit breakerWhat are there? Let's walk into Wei Kewei and communicate with their FAE to see how they explain it?

  1. Choose based on the purpose of use and the location of the electrical equipment

The residual current circuit breaker is used to prevent personal electric shock, and should be selected according to the different requirements of direct contact and indirect contact electric shock protection.

1) Protection against direct contact with electric shock

Due to the significant harm caused by direct contact with electric shock and the serious consequences, it is necessary to use highly sensitive residual current circuit breakers. For electric tools, mobile electrical equipment, and temporary circuits, residual current circuit breakers with an operating current of 30mA and an operating time of within 0.1s should be installed in the circuit. For residential buildings with a large number of household appliances, it is best to install them after the entrance energy meter. If electric shock is likely to cause secondary injury (such as high-altitude operations), a residual current circuit breaker with an operating current of 15mA and an operating time within US should be installed in the circuit. For electrical medical equipment in hospitals, residual current circuit breakers with an operating current of 6mA and an operating time within US should be installed.

小型斷路器作用

2) Indirect contact electric shock protection

Indirect contact electric shock in different places can cause varying degrees of harm to people, so different residual current circuit breakers should be installed in different places. For places with high risk of electric shock, it is required to use leakage circuit breakers with high sensitivity. The risk of electric shock is much higher in damp places than in dry places. Generally, a residual current circuit breaker with an operating current of 15-30mA and an operating time of less than 0.1s should be installed. For electrical equipment in water, a residual current circuit breaker with a current of 6-10mA and an operating time within US should be installed. For electrical equipment that operators must stand on metal objects or inside metal containers, as long as the voltage is higher than 24V, a residual current circuit breaker with an operating current of less than 15mA and an operating time within US should be installed. For fixed electrical equipment with a voltage of 220V or 380V, when the grounding resistance of the casing is below 500fZ, a single machine can install a residual current circuit breaker with an operating current of 30mA and an operating time within 0.19. For large electrical equipment with a rated current of over 100A or power supply circuits with multiple electrical devices, residual current circuit breakers with operating currents of 50-100mA can be installed. For electrical devices with grounding resistance below 1000, residual current circuit breakers with operating currents of 200-500mA can be installed.

小型斷路器作用2

After the circuit is connected, check if the wiring is correct. It can be checked through the test button. If the circuit breaker can disconnect correctly, it indicates that the leakage protector is installed correctly. Otherwise, the circuit should be checked and the fault should be eliminated. After the leakage protector is put into operation, after a certain period of time, the user should check whether the circuit breaker is running normally through the test button;.

02. The leakage, overload, and short-circuit protection characteristics of circuit breakers are set by the manufacturer and cannot be adjusted arbitrarily to avoid affecting performance; The function of the test button is to check the operating status of the circuit breaker when it is newly installed or running for a certain period of time, while it is closed and powered on. Press the test button, the circuit breaker can be disconnected, indicating normal operation and can continue to be used;

03. If the circuit breaker cannot be disconnected, it indicates that there is a fault in the circuit breaker or the line and maintenance is required;

04. If the circuit breaker breaks due to a fault (leakage, overload, or short circuit) in the protected circuit, the operating handle is in the release position (middle position). After identifying the cause and troubleshooting, the operating handle should be pulled downwards (i.e. placed in the "open" position) to make the operating mechanism "snap back" before performing the closing operation (please note the different meanings of the three positions of the circuit breaker operating handle);

After the circuit breaker is disconnected due to a short circuit in the circuit, the contacts need to be checked. If the main contacts are severely burned or have dents, maintenance is required;

06. The four pole residual current circuit breaker must be connected to the neutral line to ensure the normal operation of the electronic circuit;

07. The load wiring of the residual current circuit breaker must pass through the load end of the circuit breaker. It is not allowed for any phase or neutral line of the load to not pass through the residual current circuit breaker, otherwise it will cause artificial "leakage" and cause the circuit breaker to fail to close, resulting in "misoperation".

Weikewei's engineers are still very professional. They have compiled so much practical knowledge in such a short time. If there are similar technical issues in the future, our editor will continue to provide them to you. We welcome you to have in-depth and efficient communication and interaction with FAEs.

韋克威聯(lián)系方式


tag: 斷路器
主站蜘蛛池模板: 一区二区三区国产 | 黄色91免费| av色播 | 欧美一级片免费观看 | 久久免费在线 | 婷婷在线综合 | 亚洲激情视频 | 日韩欧美aⅴ综合网站发布 在线观看h网站 | 婷婷色亚洲| 亚洲青涩 | 美国少妇在线观看免费 | 国产精品成人69xxx免费视频 | 国产乱叫456在线 | 色婷婷国产精品久久包臀 | 女女同性被吸乳羞羞 | 国产一区二区三区欧美 | 婷婷俺来也 | 国产jzjzjz丝袜老师水多 | 人人爱人人艹 | 日韩美女av在线 | 婷婷久久丁香 | 国产91精品在线观看 | 天天射综合网站 | 午夜av免费 | 国产激情综合五月久久 | 欧美一二三 | 国产成人a人亚洲精品无码 一本毛片 | 久操av在线 | 精品成人国产 | 欧美专区在线视频 | 日韩精品在线观看一区二区 | 国产精品九九九 | 7m精品福利视频导航 | 久草福利网 | 成人免费在线观看 | 国产在线观看a | 久久免费看少妇高潮v片特黄 | 欧美 日韩 国产 精品 | 成人自拍视频在线 | 国产良妇出轨视频在线观看 | 99视频国产精品免费观看a | 久草中文网 | 在线免费小电影 | 九九热在线免费视频 | 亚洲国产精品成人综合色在线婷婷 | 亚洲综合免费观看高清完整版在线 | 黄色免费网站在线 | 影音先锋制服丝袜 | 97干视频 | 国产又爽又黄免费软件 | 黄色成人av网站 | 亚洲网在线 | 免费不卡av| 日韩中文久久 | 99热99re6国产在线播放 | 欧美精品日韩在线 | 成人免费视频国产免费网站 | 国产aaa大片| 黑人巨大精品欧美一区二区 | 人人妻人人澡人人爽欧美一区双 | 97精品在线 | 青青在线视频 | 性户外野战hd | 亚洲欧美日韩图片 | 亚欧洲精品在线视频免费观看 | 99福利在线 | 国产一区二区三区在线看 | 欧美三级午夜理伦三级老人 | 日本色妞| 日韩欧美在线观看一区二区 | 日本一道本 | 人人看人人爱 | 97国产超碰 | 狠狠激情 | 亚洲资源网站 | 国产精品爽爽爽 | 天天天天操 | 国产精品入口麻豆九色 | 超碰一区二区 | 天堂精品视频 | 高清18麻豆 | 日韩欧美国产精品综合嫩v 日韩精品久久久久久久的张开腿让 | 91视频黄色 | 免费成人进口网站 | 成人免费看片98欧美 | 亚洲精品456 | 国产小毛片 | 日韩伦乱 | 免费吃奶摸下激烈视频 | 天天宗合网 | 亚洲精品中文字幕在线 | 中文字幕在线观看第一页 | 亚洲精品自拍偷拍 | 久久午夜影院 | 99色热 | 强制高潮抽搐哭叫求饶h | 日韩一级完整毛片 | 人妻少妇偷人精品久久久任期 | 7777av|