Chongqing Fire Equipment Power Sensor Fangdeng Liushi Manufacturer Electrical City Quotation _ Power Supply

The intelligent fire equipment power monitoring system is developed based on the national standard "Fire Equipment Power Monitoring System". The system consists of a fire equipment power status monitor, a power bus, a communication bus, and connected current signal sensors, voltage signal sensors, current/voltage signal sensors, intermediate module boxes, and other devices. Through sensors, the main and backup power supplies of the fire equipment are detected in real time to determine whether the power equipment has overvoltage, undervoltage, overcurrent, open circuit, short circuit, and phase loss faults. When a fault occurs, it can quickly display and record the location, type, and time of the fault on the monitor, and emit sound and light alarm signals, effectively ensuring the reliability of the fire linkage system in the event of a fire.

Vicorv High-Reliability Electronic Components
edit
GB28184-2011 "Fire Equipment Power Monitoring System"
The national standard GB28184-2011 "Fire Equipment Power Monitoring System" is under the jurisdiction of the national fire standardization technology fire detection and alarm sub technology. It was promulgated on December 28, 2011 and implemented on August 1, 2012. This standard mandates the basic functions of the power monitoring system for firefighting equipment;
2. The design atlas of the "Fire Equipment Power Monitoring System" compiled by the China Academy of Building Standards Design and Research;
The national standard GB25506-2010 "General Technical Requirements for Fire Control Rooms" organized and compiled by the Ministry of Fire Protection stipulates that the fire control room should be able to display the working status and undervoltage alarm information of the power supply and backup power supply of each fire electrical equipment in the system.
Scope of application:
Monitoring sensors are used to detect the voltage and current values of the AC power supply circuit for firefighting equipment (normal and backup power). The sensors have
The voltage and current value monitoring selection function can be set by users according to the monitoring requirements of the power supply circuit.
Main functions:
Real time monitoring of both common and backup power sources simultaneously
The communication between sensors and monitors adopts a bus system to set addresses
Randomly set parameters such as voltage value, current value, delay time, and fault alarm output
● Relay alarm output (adjustable)
● Meet the requirements of the national standard GB28184-2011 "Fire Equipment Power Monitoring System";
Monitor the working status of the power supply for firefighting equipment;

Vicorv High-Reliability Electronic Components
Monitor faults such as overvoltage, undervoltage, and overcurrent in the power supply of fire-fighting equipment;
● Monitor power interruption and power failure of fire-fighting equipment;
Adopting DC24V working voltage to ensure system and personal safety;
Collect voltage and current signals of the monitored circuit directly with an error of less than 1%;
● Optional residual current monitoring function.
Power supply voltage: DC24V is centrally supplied by the regional extension or host
Bus communication method: CAN bus
Power line+communication line: NH-BV-2 * 2.5mm2 (power line)+ZR-RVS-2 * 1.5mm2 (communication line)
Output parameters: 1 passive contact, alarm or control output
Address code: Each sensor has an address code, which is randomly set
Isolator: Each sensor comes with its own isolator
Alarm delay: adjustable from 0 to 30 seconds, can be set on site

Vicorv High-Reliability Electronic Components
Alarm parameters: 85% of undervoltage rated voltage, 110% of overvoltage rated voltage: overcurrent according to the current transformer ratio setting value of 25%
Alarm display: LED display with sound and light alarm
Environmental temperature: -20 ℃~+70 ℃
Protection level: P30

Vicorv High-Reliability Electronic Components
Installation method: Standard 35mm rail installation
Flexibly build a capacity fire equipment power monitoring system by connecting with the upper computer, domain extension, signal acquisition module, etc; The system adopts a non open operation mode, with self-management within the system and one-way transmission of information to the outside world; Adopting a centralized power supply method to provide DC24V safe voltage to on-site modules, effectively ensuring the stability and safety of the system; The output circuit can be flexibly expanded through domain extensions to meet the complex and ever-changing requirements of modern architecture; Monitor the working status and fault alarm information of all fire-fighting equipment and backup power sources, and transmit the working status and alarm information to the graphic display device in the fire control room; The system has the characteristics of reliability, timeliness, and continuous monitoring with digitization, intelligence, networking, and automation. Reflecting the power status of the monitored equipment and displaying it in a centralized manner can effectively avoid the danger of firefighting equipment being unable to function properly due to power failure during a fire, thus ensuring the reliability of the firefighting linkage system to the fullest extent possible; The series fire equipment power monitoring system adopts a three-layer network structure of electrical equipment+monitoring module+system machine, which simplifies the system structure design. The entire monitoring system is safe, reliable, accurate in detection, and cost-effective. The system uses CAN network communication internally and provides Modbus RTU communication protocol externally to meet the connection requirements of other standard systems; The entire series of sensors are powered by a 24V DC safe voltage, ensuring both personal safety and stable operation of the entire system;

Vicorv High-Reliability Electronic Components

主站蜘蛛池模板: 欧美高清另类 | 国模二区| 免费久久| 亚洲精品福利在线观看 | 欧美高清视频一区 | 中文字幕在线观看视频免费 | 五月婷婷,六月丁香 | www.人人草| 精品久久久久久久久久久久久久久 | 国产视频一 | 亚洲激情视频在线 | 国产偷拍一区二区三区 | 激情视频在线免费观看 | 一区免费在线观看 | 精品久久久久久亚洲 | 青青草视频免费 | 亚洲视频中文字幕在线观看 | 韩国美女毛片 | 欧美激情成人 | 成人av电影在线观看 | 多啪啪免费视频 | 亚洲一区毛片 | 欧美人与性动交α欧美精品 | 人妻少妇无码精品视频区 | 国产精品久久久久蜜臀 | www.亚洲色图 | 精品国产露脸精彩对白 | 懂色av一区二区三区四区 | 91无打码 | 欧美性生活 | 日韩av大片在线观看 | 一区二区三区国产精品 | 国产在线一卡二卡 | 国产啊啊啊啊 | 久久久亚洲欧洲 | 神马午夜我不卡 | 可以看的av网站 | 欧美最顶级a∨艳星 | 亚洲天堂色图 | 国产一伦一伦一伦 | 国产精品国产三级国产在线观看 | 性生交大片免费看狂欲 | 久久久久亚洲av无码专区首jn | 亚洲片国产一区一级在线观看 | 天天成人 | 91精品国自产在线偷拍蜜桃 | 国产成人久久精品77777综合 | 91大神在线观看视频 | 免费成人福利视频 | 午夜激情视频在线 | 粉嫩av一区二区 | 欧美精品一区在线观看 | 96精品视频在线观看 | 好av在线 | 日日夜夜天天综合 | 中文字幕乱码免费 | 在线天堂一区 | 中文字幕首页 | 动漫美女无遮挡免费 | 欧美日韩精品在线视频 | 精品国产无码一区二区 | 伊人老司机 | 国产女人爽到高潮a毛片 | 女人脱下裤子让男人捅 | 日日夜夜天天干 | 丁香六月婷婷激情 | 91麻豆一区二区 | 中文字幕一区二区三区人妻四季 | 国产精品青青草 | 国产片一区二区三区 | 1024手机看片日韩 | 亚洲天堂成人在线观看 | 一区二区视频网 | 色欲一区二区三区精品a片 美日韩av在线 | 正在播放一区二区 | 国产在线播放网站 | 成人影视免费观看 | 免费视频www在线观看网站 | 影音先锋欧美资源 | 成人做爰www看视频软件 | 国产精品性色 | 日韩乱码人妻无码中文字幕久久 | 一级黄色短视频 | 五月婷婷亚洲综合 | 告诉我真相俄剧在线观看 | 国产极品在线观看 | 99久久久国产精品免费蜜臀 | 草草影院最新地址 | 久久综合久久久久 | 亚洲精品视频观看 | 日韩欧美在线观看免费 | 伦理片波多野结衣 | 日吊视频 | 欧美成人性色 | 美国少妇性做爰 | 成人亚洲一区二区 | 国产一区二区自拍视频 | 一级片毛片| 亚洲 欧美 中文字幕 |