DBC-1,3 pull-out free tripping single-phase circuit breaker products work on the nickel chromium wire electric heating principle and are used for overload or short circuit protection in aircraft AC/DC distribution systems.

Environmental adaptability:
- Surrounding medium temperature: (-55~sixty) ℃. 
- Sinusoidal vibration: frequency range (10-200) Hz, acceleration four.5g 
- Acceleration: 8g 
- Impact: speed 40-100 times/min, acceleration 4 g, total 104Next time. 
Electrical performance:
Extreme action current
- 60At ℃, the maximum holding current of the product is the rated current 
- At 60 ℃, the minimum tripping current of the product is 180% of the rated current 
- -At 55 ℃, the minimum tripping current of the product is 200% of the rated current  
life:In a DC or AC circuit, connect and disconnect the rated current 3000 times.