Basic parameters, working principle and purpose:
The DDB-AB125-AB200 pull-out free tripping single-phase circuit breaker products work on the principle of bimetallic electric thermal tripping. The circuit breaker is used for overload or short circuit protection in aircraft AC/DC distribution systems.

Environmental adaptability:
- Surrounding medium temperature: (-55~70) ℃ 
- Sinusoidal vibration: frequency range (10-2000) Hz 
- Acceleration: 10g 
- Impact: 30g 
Electrical performance:
- Extreme action current 
At 25 ℃, the maximum holding current of the product is 100% of the rated current, and the minimum tripping current is 150% of the rated current
At 70 ℃, the maximum holding current of the product is 80% of the rated current, and the minimum tripping current is 145% of the rated current
-At 55 ℃, the maximum holding current of the product is 110% of the rated current, and the minimum tripping current is 180% of the rated current
- Overload current and action time  
- life 
5000 working cycles under AC resistive load; 2500 cycles of inductive load operation
5000 working cycles under DC resistive load

- Breaking ability 
DC 3000A; Communication 2500 A
Exterior installation dimensions: